- Surface pavement layer thickness can typically be determined to ~0.2 to 0.4 inches (~5 to 10 mm) along with Young’s moduli (asphalt moduli is temperature corrected)
|
|
|
|
|
|
- MISW offers improved accuracy vs. other surface wave methods for thickness/Young’s Moduli profiles
|
|
|
|
|
|
- Real-time waveform display and surface layer data processing while testing
|
|
|
|
|
|
- SeisNDT-SL Single Layer software (by Dr. Nils Ryden) for QA of thickness/moduli
of pavement (asphalt/concrete), base
(gravel, cement, or lime-treated roadbase materials), and subgrade
layers during new construction
|
|
|
|
|
|
- NDE 360 MISW systems are compact, durable, and easily transported allowing for multiple tests per day and field analysis of top layer results
|
|
|
|
|
|
- SeisNDT-ML Multiple Layer software for forensic thickness/moduli determination of pavements and other layered systems (includes SeisNDT-SL for Single Layer Systems)
|
|
|
|
|
|
- Freedom Data PC MISW system allows for field analysis of top layer results and more detailed field processing of data
|
|
|
|
|
|
|
|
|